TCSHT33-128/30A/25℃
TERTRON
Description
This equipment (TCSHT33-128/30A/25℃) is a thermostatic cylindrical battery testing device designed specifically for regions with extreme weather conditions (heavy snow/extreme cold). It provides an optimal testing environment with a constant temperature of 25°C, enabling accurate testing of battery capacity, lifespan, and charge/discharge performance. This significantly enhances battery testing efficiency and accuracy.
Key Features
- Tailored for cylindrical power batteries, ensuring compatibility with various sizes and chemistries.
- Designed for extreme weather regions, it can maintain a constant 25°C test temperature.
- Each battery test channel has an independent voltage and current loop design, which is stable and impact-free. It can realize functions such as start, stop, pause, continue and protection for a single battery channel.
- Advanced energy-saving capacity grading technology for accurate assessment of battery performance.
- Customizable grading parameters to accommodate specific battery chemistries and performance specifications.
- Automated sorting processes streamline operations and maximize throughput.
- High precision measurement tools provide reliable grading results in real-time.
- Comprehensive safety features ensure operator safety and prevent accidents.
- Intuitive user interface simplifies operation and monitoring for enhanced efficiency.
Product Parameters
Structure Of Equipment | |||
Device Channel | 128 channels | Overall Dimension | Length 1740mm× Width 800mm× Height 2296mm |
Support Battery Specifications | 32~60 series batteries (adjust by replacing the battery tray) | ||
Working Power Supply | Three-phase 5 wire system AC380V±10%,50HZ | ||
Working Power Consumption | ≤24KW | ||
Heating Power Consumption | <2KW | ||
Channel Parameters | |||
Charging Voltage Range | DC 0mV~4.5V | Discharging Voltage Range | DC 2V~4.5V |
Constant Voltage Range | DC 2~4.5V | Voltage Measurement Range | DC 0V~5V |
Voltage Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) | Voltage Control/Sampling Resolution | 0.1mV |
Charging/Discharging Current Range | 60mA~30A | ||
Current Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) | Current Control/Sampling Resolution | 1mA |
Time Measurement Control Accuracy | ≤±0.1% | ||
Constant Temperature Function | 25±2℃ inside the cabinet | ||
Software Function | |||
Control Method | Computer control equipment operation, whole cabinet control, with scanning system | ||
Process Settings | A maximum of 64 step parameters and 256 cycles can be set | ||
Charging Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | ||
Charging Cut-off Conditions | Voltage, current, time, capacity, -△V | ||
Discharge Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | ||
Discharge Cut-off Conditions | voltage, time, capacity | ||
Protection Functions | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery |
The above is the applicable battery size for Standardized Battery Capacity Testers. If you have other battery sizes,
Description
This equipment (TCSHT33-128/30A/25℃) is a thermostatic cylindrical battery testing device designed specifically for regions with extreme weather conditions (heavy snow/extreme cold). It provides an optimal testing environment with a constant temperature of 25°C, enabling accurate testing of battery capacity, lifespan, and charge/discharge performance. This significantly enhances battery testing efficiency and accuracy.
Key Features
- Tailored for cylindrical power batteries, ensuring compatibility with various sizes and chemistries.
- Designed for extreme weather regions, it can maintain a constant 25°C test temperature.
- Each battery test channel has an independent voltage and current loop design, which is stable and impact-free. It can realize functions such as start, stop, pause, continue and protection for a single battery channel.
- Advanced energy-saving capacity grading technology for accurate assessment of battery performance.
- Customizable grading parameters to accommodate specific battery chemistries and performance specifications.
- Automated sorting processes streamline operations and maximize throughput.
- High precision measurement tools provide reliable grading results in real-time.
- Comprehensive safety features ensure operator safety and prevent accidents.
- Intuitive user interface simplifies operation and monitoring for enhanced efficiency.
Product Parameters
Structure Of Equipment | |||
Device Channel | 128 channels | Overall Dimension | Length 1740mm× Width 800mm× Height 2296mm |
Support Battery Specifications | 32~60 series batteries (adjust by replacing the battery tray) | ||
Working Power Supply | Three-phase 5 wire system AC380V±10%,50HZ | ||
Working Power Consumption | ≤24KW | ||
Heating Power Consumption | <2KW | ||
Channel Parameters | |||
Charging Voltage Range | DC 0mV~4.5V | Discharging Voltage Range | DC 2V~4.5V |
Constant Voltage Range | DC 2~4.5V | Voltage Measurement Range | DC 0V~5V |
Voltage Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) | Voltage Control/Sampling Resolution | 0.1mV |
Charging/Discharging Current Range | 60mA~30A | ||
Current Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) | Current Control/Sampling Resolution | 1mA |
Time Measurement Control Accuracy | ≤±0.1% | ||
Constant Temperature Function | 25±2℃ inside the cabinet | ||
Software Function | |||
Control Method | Computer control equipment operation, whole cabinet control, with scanning system | ||
Process Settings | A maximum of 64 step parameters and 256 cycles can be set | ||
Charging Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | ||
Charging Cut-off Conditions | Voltage, current, time, capacity, -△V | ||
Discharge Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | ||
Discharge Cut-off Conditions | voltage, time, capacity | ||
Protection Functions | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery |