Availability: | |
---|---|
Quantity: | |
P30-64-30A & P20-288-10A
TERTRON
Equipment Structure | ||
Equipment Model | P30-64-30A | P20-288-10A |
Number of Equipment Channels | 64 channels | 288 channels |
Dimensions | L630xW579xH480mm | L1680xW473.5xH389.5mm |
Chassis color | standard off-white (can be customized) | |
Clamp type | CH/VH socket | |
Working power supply | three-phase five-wire AC380±10%, 50HZ | |
Working power consumption | ≤12KW | ≤18KW |
Working environment temperature | 0~40℃, relative humidity ≤80% | |
Heat dissipation method | natural air intake, upward or downward exhaust | |
Channel Parameters | ||
Charge Voltage Range | DC 0mV~4.5V | DC 0mV~4.5V |
Discharge Voltage Range | DC 2V~4.5V | DC 2V~4.5V |
Constant Voltage Range | DC 2~4.5V | DC 2~4.5V |
Voltage Measurement Range | DC 0V~5V | DC 0V~5V |
Voltage Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) | ±(0.5‰ reading + 0.5‰ full scale) |
Voltage Control/Sampling Resolution | 0.1mV | 1mV |
Charging/Discharging Current Range | 60mA~30A | 50mA~10A |
Current Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) | ±(0.5‰ reading + 0.5‰ full scale) |
Current Control/Sampling Resolution | 1mA | 1mA |
Time Measurement Control Accuracy | ≤±0.1% | ≤±0.1% |
Software Function | ||
Control Method | Computer control equipment operation, whole cabinet control, with scanning system | |
Process Settings | A maximum of 64 step parameters and 256 cycles can be set | |
Charging Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | |
Charging Cut-off Conditions | Voltage, current, time, capacity, -△V | |
Discharge Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | |
Discharge Cut-off Conditions | voltage, time, capacity | |
Protection Functions | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery |
Equipment Structure | ||
Equipment Model | P30-64-30A | P20-288-10A |
Number of Equipment Channels | 64 channels | 288 channels |
Dimensions | L630xW579xH480mm | L1680xW473.5xH389.5mm |
Chassis color | standard off-white (can be customized) | |
Clamp type | CH/VH socket | |
Working power supply | three-phase five-wire AC380±10%, 50HZ | |
Working power consumption | ≤12KW | ≤18KW |
Working environment temperature | 0~40℃, relative humidity ≤80% | |
Heat dissipation method | natural air intake, upward or downward exhaust | |
Channel Parameters | ||
Charge Voltage Range | DC 0mV~4.5V | DC 0mV~4.5V |
Discharge Voltage Range | DC 2V~4.5V | DC 2V~4.5V |
Constant Voltage Range | DC 2~4.5V | DC 2~4.5V |
Voltage Measurement Range | DC 0V~5V | DC 0V~5V |
Voltage Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) | ±(0.5‰ reading + 0.5‰ full scale) |
Voltage Control/Sampling Resolution | 0.1mV | 1mV |
Charging/Discharging Current Range | 60mA~30A | 50mA~10A |
Current Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) | ±(0.5‰ reading + 0.5‰ full scale) |
Current Control/Sampling Resolution | 1mA | 1mA |
Time Measurement Control Accuracy | ≤±0.1% | ≤±0.1% |
Software Function | ||
Control Method | Computer control equipment operation, whole cabinet control, with scanning system | |
Process Settings | A maximum of 64 step parameters and 256 cycles can be set | |
Charging Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | |
Charging Cut-off Conditions | Voltage, current, time, capacity, -△V | |
Discharge Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | |
Discharge Cut-off Conditions | voltage, time, capacity | |
Protection Functions | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery |