This equipment (TCA39-48/60A) is mainly used to test the voltage, capacity and other parameters of prismatic aluminum shell battery segments, and classify the batteries according to the test results, analyze the data, and upload and share them. The equipment has 48 channels, divided into two storage locations, with 24 channels in each location. Each battery has its own independent constant current and voltage source, which is stable and impact-free.


Key Features

- Single-point independence, each battery has an independent constant current and constant voltage source, which is stable and impact-free.

- The equipment is controlled by APM32 single-chip microcomputer and connected to a computer. It can save all test data and curves, and can also be operated directly through the keyboard of the equipment to set the process to complete the test and sort.

- Real-time detection and display of the status of each battery. If there is an abnormality, the channel will stop working and the indicator light will be on.

- It has a power-off protection function, and can continue to run the original workflow after a call.

- The power tube uses a field effect tube, which is suitable for batteries with lower voltage discharge, such as lithium iron phosphate batteries.

- The graphical operation interface is intuitive and clear. It displays the voltage, current, time, capacity and other data of each battery at the same time, and can set different colors to display the corresponding working status and abnormal conditions.

- The equipment accuracy is 0.05%, the data recording time is 1 second/time, and the stability is high.

- The software is powerful and the human-machine interface is friendly.

- The four-wire test interface ensures high measurement accuracy.

- Modular design concept, easy to maintain.

- The needle bed automatic equipment mode (can be used according to the turnover box design provided by the customer), one tray per layer, each tray loads 24 batteries, and a single row and double layers load a total of 48 batteries.

- According to actual measurements, the power consumption of this equipment during charging is more than 40% less than that of traditional equipment, the comprehensive power saving rate is more than 60%, and the power consumption is saved by more than 60%, which saves a lot of costs for battery manufacturers.



Product Parameters

Structure Of Equipment

Device Channel

48 channels Overall Dimension Length 1080mm× Width 1700mm× Height 2180mm

Support Battery Specifications

Customized according to customer needs

Working Power Supply

Three-phase 5 wire system AC380V±10%,50HZ
Working Power Consumption ≤8KW
Heating Power Consumption <8KW
Channel Parameters
Charging Voltage Range

DC 0mV~4.5V

Discharging Voltage Range DC 2V~4.5V

Constant Voltage Range

DC 2~4.5V

Voltage Measurement Range DC 0V~5V

Voltage Measurement Control Accuracy

±(0.5‰ reading + 0.5‰ full scale) Voltage Control/Sampling Resolution 0.1mV
Charging/Discharging Current Range 120mA~60A
Current Measurement Control Accuracy ±(0.5‰ reading + 0.5‰ full scale) Current Control/Sampling Resolution 1mA
Time Measurement Control Accuracy ≤±0.1% Heating Range 20-70℃ (±3℃ adjustable)

Pressure Range

(-90KPa-0) adjustable (±5kPa)

Software Function

Control Method

Computer control equipment operation, whole cabinet control, with scanning system

Process Settings

A maximum of 64 step parameters and 256 cycles can be set

Charging Mode

Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance

Charging Cut-off Conditions

Voltage, current, time, capacity, -△V

Discharge Mode

Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance

Discharge Cut-off Conditions

voltage, time, capacity

Protection Functions

Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery

The above is the applicable battery size for Standardized Battery Capacity Testers. If you have other battery sizes,




application for battery pack - 1


CONTACT US

Phone:+86-19802015763
Email:inbox@terlipower.com
WhatsApp:+86-19802015763
Add:BLDG B1 No. 193 Jinlong Road, Dalong Street, Panyu District, Guangzhou, China
Add:213 Shinan Road, Nansha District, Guangzhou, China

QUICK LINKS

PRODUCTS CATEGORY

KEEP IN TOUCH WITH US
Copyright © 2024 Guangzhou TERTRON New Energy Technology Co., Ltd. | Sitemap | Support by leadong.com | Privacy Policy