This system (TCAFT39-576-10A) is mainly used for semi-automatic production of cylindrical lithium battery formation and capacity grading (OCV test and grading process are provided by the customer). The equipment uses pallets as battery carriers, accepts pallets conveyed by loading and unloading carts, and then completes the battery activation, capacity grading, open circuit voltage, AC internal resistance and other process tasks.
Availability: | |
---|---|
Quantity: | |
TCAFT39-576-10A
TERTRON
Description
This system (TCAFT39-576-10A) is mainly used for semi-automatic production of cylindrical lithium battery formation and capacity grading (OCV test and grading process are provided by the customer). The equipment uses pallets as battery carriers, accepts pallets conveyed by loading and unloading carts, and then completes the battery activation, capacity grading, open circuit voltage, AC internal resistance and other process tasks.
Key Features
- Tailored for cylindrical power batteries, ensuring compatibility with various sizes and chemistries.
- Each battery test channel has an independent voltage and current loop design, which is stable and impact-free. It can realize functions such as start, stop, pause, continue and protection for a single battery channel.
- Advanced energy-saving capacity grading technology for accurate assessment of battery performance.
- Customizable grading parameters to accommodate specific battery chemistries and performance specifications.
- Automated sorting processes streamline operations and maximize throughput.
- High precision measurement tools provide reliable grading results in real-time.
- Comprehensive safety features ensure operator safety and prevent accidents.
- Intuitive user interface simplifies operation and monitoring for enhanced efficiency.
- Quality assurance mechanisms categorize batteries based on performance metrics, ensuring adherence to strict quality standards.
Specifications
Category | Model specifications | Dimensions (diameter x height mm) |
Battery Blueprint | 33140 | 33 x 140 |
Compatible Battery | 35140 | 35 x 140 |
The above is the applicable battery size for Standardized Battery Capacity Testers. If you have other battery sizes,
Product Parameters
Structure Of Equipment | |||
Device Channel | 576 channels | Overall Dimension | Length 1450mm× Width 1600mm× Height 2680mm |
Support Battery Specifications | 33140、35140 battery models (Customized according to customer needs) | ||
Working Power Supply | Three-phase 5 wire system AC380V±10%,50HZ | ||
Working Power Consumption | ≤36KW | ||
Heating Power Consumption | <8KW | ||
Channel Parameters | |||
Charging Voltage Range | DC 0mV~4.5V | Discharging Voltage Range | DC 2V~4.5V |
Constant Voltage Range | DC 2~4.5V | Voltage Measurement Range | DC 0V~5V |
Voltage Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) | Voltage Control/Sampling Resolution | 0.1mV |
Charging/Discharging Current Range | 20mA~10A | ||
Current Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) | Current Control/Sampling Resolution | 1mA |
Time Measurement Control Accuracy | ≤±0.1% | Heating Range | 20-70℃ (±3℃ adjustable) |
Pressure Range | -100kPa~100kPa | ||
Software Function | |||
Control Method | Computer control equipment operation, whole cabinet control, with scanning system | ||
Process Settings | A maximum of 64 step parameters and 256 cycles can be set | ||
Charging Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | ||
Charging Cut-off Conditions | Voltage, current, time, capacity, -△V | ||
Discharge Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | ||
Discharge Cut-off Conditions | voltage, time, capacity | ||
Protection Functions | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery |
Description
This system (TCAFT39-576-10A) is mainly used for semi-automatic production of cylindrical lithium battery formation and capacity grading (OCV test and grading process are provided by the customer). The equipment uses pallets as battery carriers, accepts pallets conveyed by loading and unloading carts, and then completes the battery activation, capacity grading, open circuit voltage, AC internal resistance and other process tasks.
Key Features
- Tailored for cylindrical power batteries, ensuring compatibility with various sizes and chemistries.
- Each battery test channel has an independent voltage and current loop design, which is stable and impact-free. It can realize functions such as start, stop, pause, continue and protection for a single battery channel.
- Advanced energy-saving capacity grading technology for accurate assessment of battery performance.
- Customizable grading parameters to accommodate specific battery chemistries and performance specifications.
- Automated sorting processes streamline operations and maximize throughput.
- High precision measurement tools provide reliable grading results in real-time.
- Comprehensive safety features ensure operator safety and prevent accidents.
- Intuitive user interface simplifies operation and monitoring for enhanced efficiency.
- Quality assurance mechanisms categorize batteries based on performance metrics, ensuring adherence to strict quality standards.
Specifications
Category | Model specifications | Dimensions (diameter x height mm) |
Battery Blueprint | 33140 | 33 x 140 |
Compatible Battery | 35140 | 35 x 140 |
The above is the applicable battery size for Standardized Battery Capacity Testers. If you have other battery sizes,
Product Parameters
Structure Of Equipment | |||
Device Channel | 576 channels | Overall Dimension | Length 1450mm× Width 1600mm× Height 2680mm |
Support Battery Specifications | 33140、35140 battery models (Customized according to customer needs) | ||
Working Power Supply | Three-phase 5 wire system AC380V±10%,50HZ | ||
Working Power Consumption | ≤36KW | ||
Heating Power Consumption | <8KW | ||
Channel Parameters | |||
Charging Voltage Range | DC 0mV~4.5V | Discharging Voltage Range | DC 2V~4.5V |
Constant Voltage Range | DC 2~4.5V | Voltage Measurement Range | DC 0V~5V |
Voltage Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) | Voltage Control/Sampling Resolution | 0.1mV |
Charging/Discharging Current Range | 20mA~10A | ||
Current Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) | Current Control/Sampling Resolution | 1mA |
Time Measurement Control Accuracy | ≤±0.1% | Heating Range | 20-70℃ (±3℃ adjustable) |
Pressure Range | -100kPa~100kPa | ||
Software Function | |||
Control Method | Computer control equipment operation, whole cabinet control, with scanning system | ||
Process Settings | A maximum of 64 step parameters and 256 cycles can be set | ||
Charging Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | ||
Charging Cut-off Conditions | Voltage, current, time, capacity, -△V | ||
Discharge Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | ||
Discharge Cut-off Conditions | voltage, time, capacity | ||
Protection Functions | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery |