You are here: Home » Products » Capacity Grading Machine » Cylindrical Cell Tester » 1280 Channel Pin-Bed Cylindrical Battery Capacity Grading Machine (TCA39-1280/3A)
KEEP IN TOUCH WITH US

1280 Channel Pin-Bed Cylindrical Battery Capacity Grading Machine (TCA39-1280/3A)

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
  • TCA39-1280/3A

  • TERTRON

1280 Channel Pin-Bed Cylindrical Battery Capacity Grading Machine (3)


Description

This equipment (TCA39-1280/3A) mainly tests the voltage, capacity and other parameters of cylindrical battery formation/capacity grading, and classifies the battery according to the test results, analyzes the data, and uploads and shares them. It adopts a needle bed tray carrier design with more than 1280 channels; the battery is single-point independent, and each battery has an independent constant current and constant voltage source, which is stable and impact-free. It adopts an 8/16-channel programmable constant current and constant voltage control module.


Key Features

- Single-point independence, each battery has a completely independent constant current and constant voltage source, which is stable and impact-free. It adopts an 8/16-channel program-controlled constant current and constant voltage control module.

- The equipment is controlled by STC51 single-chip microcomputer and connected to a computer. It can save all test data and curves, and can also be operated directly through the keyboard of the equipment to set the process to complete the test and sort.

- Real-time detection and display of the status of each battery. If there is an abnormality, the channel will stop working and the indicator light will be on.

- It has a power-off protection function, and can continue to run the original workflow after a call.

- The power tube uses a field effect tube, which is suitable for batteries with lower voltage discharge, such as lithium iron phosphate batteries.

- The graphical operation interface is intuitive and clear. It displays the voltage, current, time, capacity and other data of each battery at the same time, and can set different colors to display the corresponding working status and abnormal conditions.

- The equipment accuracy is 0.05%, the data recording time is 1 second/time, and the stability is high.

- The software is powerful and the human-machine interface is friendly.

- The four-wire test interface ensures high measurement accuracy.

- Modular design concept, easy to maintain.

- The needle bed type automatic equipment mode (can be used in conjunction with the turnover box design provided by the customer), two trays per layer, each tray is loaded with 160 batteries, and the double-row four-layer is loaded with a total of 1280 batteries.



Equipment Engineering Dimensions



Product Parameters

Structure Of Equipment

Device Channel

1280 channels Overall Dimension Length 1300mm× Width 1350mm× Height 1770mm

Support Battery Specifications

18650 series (need to replace the tray)

Working Power Supply

Three-phase 5 wire system AC380V±10%,50HZ
Working Power Consumption ≤27KW
Channel Parameters
Charging Voltage Range

DC 0mV~4.5V

Discharging Voltage Range DC 2V~4.5V

Constant Voltage Range

DC 2~4.5V

Voltage Measurement Range DC 0V~5V

Voltage Measurement Control Accuracy

±(0.5‰ reading + 0.5‰ full scale) Voltage Control/Sampling Resolution 0.1mV
Charging/Discharging Current Range 10mA~3A
Current Measurement Control Accuracy ±(0.5‰ reading + 0.5‰ full scale) Current Control/Sampling Resolution 1mA
Time Measurement Control Accuracy ≤±0.1%
Software Function

Control Method

Computer control equipment operation, whole cabinet control, with scanning system

Process Settings

A maximum of 64 step parameters and 256 cycles can be set

Charging Mode

Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance

Charging Cut-off Conditions

Voltage, current, time, capacity, -△V

Discharge Mode

Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance

Discharge Cut-off Conditions

voltage, time, capacity

Protection Functions

Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery

The above is the applicable battery size for Standardized Battery Capacity Testers. If you have other battery sizes,



application for battery pack - 1



CONTACT US

Phone:+86-19802015763
Email:inbox@terlipower.com
WhatsApp:+86-19802015763
Add:BLDG B1 No. 193 Jinlong Road, Dalong Street, Panyu District, Guangzhou, China
Add:213 Shinan Road, Nansha District, Guangzhou, China

QUICK LINKS

PRODUCTS CATEGORY

KEEP IN TOUCH WITH US
Copyright © 2024 Guangzhou TERTRON New Energy Technology Co., Ltd. | Sitemap | Support by leadong.com | Privacy Policy