P10-128-10A & P10-256-6A
TERTRON
Equipment Structure | ||
Equipment Model | P10-128-10A | P10-256-6A |
Number of Equipment Channels | 128 channels | 256 channels |
Dimensions | L950xW750xH350mm | L1780xW370xH340mm |
Working power supply | three-phase five-wire AC380±10%, 50HZ | |
Working power consumption | ≤11.2KW | ≤13.5KW |
Working environment temperature | 0~40℃, relative humidity ≤80% | |
Heat dissipation method | natural air intake, upward or downward exhaust | |
Channel Parameters | ||
Charge Voltage Range | DC 0mV~4.5V | DC 0mV~4.5V |
Discharge Voltage Range | DC 2V~4.5V | DC 2V~4.5V |
Constant Voltage Range | DC 2~4.5V | DC 2~4.5V |
Voltage Measurement Range | DC 0V~5V | DC 0V~5V |
Voltage Measurement Control Accuracy | ±(0.1‰ reading + 0.1‰ full scale) | ±(0.1‰ reading + 0.1‰ full scale) |
Voltage Control/Sampling Resolution | 1mV | 1mV |
Charging/Discharging Current Range | 50mA~10A | 10mA~6A |
Current Measurement Control Accuracy | ±(0.1‰ reading + 0.1‰ full scale) | ±(0.1‰ reading + 0.1‰ full scale) |
Current Control/Sampling Resolution | 1mA | 1mA |
Time Measurement Control Accuracy | ≤±0.1% | ≤±0.1% |
Software Function | ||
Control Method | Computer control equipment operation, whole cabinet control, with scanning system | |
Process Settings | A maximum of 64 step parameters and 256 cycles can be set | |
Charging Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | |
Charging Cut-off Conditions | Voltage, current, time, capacity, -△V | |
Discharge Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | |
Discharge Cut-off Conditions | voltage, time, capacity | |
Protection Functions | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery |
Equipment Structure | ||
Equipment Model | P10-128-10A | P10-256-6A |
Number of Equipment Channels | 128 channels | 256 channels |
Dimensions | L950xW750xH350mm | L1780xW370xH340mm |
Working power supply | three-phase five-wire AC380±10%, 50HZ | |
Working power consumption | ≤11.2KW | ≤13.5KW |
Working environment temperature | 0~40℃, relative humidity ≤80% | |
Heat dissipation method | natural air intake, upward or downward exhaust | |
Channel Parameters | ||
Charge Voltage Range | DC 0mV~4.5V | DC 0mV~4.5V |
Discharge Voltage Range | DC 2V~4.5V | DC 2V~4.5V |
Constant Voltage Range | DC 2~4.5V | DC 2~4.5V |
Voltage Measurement Range | DC 0V~5V | DC 0V~5V |
Voltage Measurement Control Accuracy | ±(0.1‰ reading + 0.1‰ full scale) | ±(0.1‰ reading + 0.1‰ full scale) |
Voltage Control/Sampling Resolution | 1mV | 1mV |
Charging/Discharging Current Range | 50mA~10A | 10mA~6A |
Current Measurement Control Accuracy | ±(0.1‰ reading + 0.1‰ full scale) | ±(0.1‰ reading + 0.1‰ full scale) |
Current Control/Sampling Resolution | 1mA | 1mA |
Time Measurement Control Accuracy | ≤±0.1% | ≤±0.1% |
Software Function | ||
Control Method | Computer control equipment operation, whole cabinet control, with scanning system | |
Process Settings | A maximum of 64 step parameters and 256 cycles can be set | |
Charging Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | |
Charging Cut-off Conditions | Voltage, current, time, capacity, -△V | |
Discharge Mode | Constant current, constant voltage, constant current constant voltage/constant current, constant power, constant resistance | |
Discharge Cut-off Conditions | voltage, time, capacity | |
Protection Functions | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery |