Equipment model | P10-256/5 (long, short) | P10-128/5 | P10-512/2 | P10-128/10 |
Equipment model | P10-256/6 (long, short) | P10-128/6 | P10-512/3 | P10-128/20 |
Equipment structure | ||||
Number of equipment channels: | 256 channels in total | 28 channels | 512 channels | 128 channels |
Dimensions (length*width*heightMM) | 1780*370*340/1280*400*520 | 960*370*340 | 1840*400*510 | 950*750*350 |
Chassis color | standard off-white (can be customized) | |||
Clamp type | CH/VH socket | |||
Working power supply | three-phase five-wire AC380±10%, 50HZ | |||
Working power consumption | 11KW | 5.5KW | 9KW | 11KW |
Working environment temperature | 0~40℃, relative humidity ≤80% | |||
Heat dissipation method | natural air intake, upward or downward exhaust | |||
Channel Parameters | ||||
Voltage measurement range | 0-5V, resolution 1mV | |||
Battery voltage range | charging 0-4.5V, discharging 4.5-2V | |||
Constant voltage range | 2.5-4.5V | |||
Voltage accuracy | ±(0.1% reading +0.1% full scale) | |||
Current range | 50mA- 5A, resolution (R) 1mA | 50mA-5A;(R)1mA | 20mA-2A;(R)1mA | 0.1-10A;(R)10MA |
Current range | 60mA- 6A, resolution (R) 1mA | 60mA-6A;(R)1mA | 30mA-3A;(R)1mA | |
Current accuracy | ±(0.1%o reading +0.1% full scale | |||
Software Function | ||||
Control mode | computer connection equipment work, whole cabinet control | |||
Communication method | RS485, baud rate 57600 | |||
Process settings | can set up to 32 steps and 256 cycles | |||
Charging mode | constant current, constant voltage | |||
Charging end conditions | voltage, current, time, capacity Discharge mode constant current | |||
Discharge mode | constant current | |||
Discharge end conditions | voltage, time, capacity | |||
Protection functions | overvoltage, undervoltage, overcurrent, undercurrent, overcapacity, etc. | |||
Time range | arbitrarily set within 0-30000 minutes | |||
Time accuracy | ≤1% | |||
Sampling inspection cycle | ≤5s | ≤3s | ≤8s | ≤3s |
Minimum data recording frequency | ≤5s | ≤8s | ||
Battery sorting | according to capacity, time, discharge platform, etc. | |||
Data processing | Data, graphs and cycle diagrams |
Equipment model | P10-256/5 (long, short) | P10-128/5 | P10-512/2 | P10-128/10 |
Equipment model | P10-256/6 (long, short) | P10-128/6 | P10-512/3 | P10-128/20 |
Equipment structure | ||||
Number of equipment channels: | 256 channels in total | 28 channels | 512 channels | 128 channels |
Dimensions (length*width*heightMM) | 1780*370*340/1280*400*520 | 960*370*340 | 1840*400*510 | 950*750*350 |
Chassis color | standard off-white (can be customized) | |||
Clamp type | CH/VH socket | |||
Working power supply | three-phase five-wire AC380±10%, 50HZ | |||
Working power consumption | 11KW | 5.5KW | 9KW | 11KW |
Working environment temperature | 0~40℃, relative humidity ≤80% | |||
Heat dissipation method | natural air intake, upward or downward exhaust | |||
Channel Parameters | ||||
Voltage measurement range | 0-5V, resolution 1mV | |||
Battery voltage range | charging 0-4.5V, discharging 4.5-2V | |||
Constant voltage range | 2.5-4.5V | |||
Voltage accuracy | ±(0.1% reading +0.1% full scale) | |||
Current range | 50mA- 5A, resolution (R) 1mA | 50mA-5A;(R)1mA | 20mA-2A;(R)1mA | 0.1-10A;(R)10MA |
Current range | 60mA- 6A, resolution (R) 1mA | 60mA-6A;(R)1mA | 30mA-3A;(R)1mA | |
Current accuracy | ±(0.1%o reading +0.1% full scale | |||
Software Function | ||||
Control mode | computer connection equipment work, whole cabinet control | |||
Communication method | RS485, baud rate 57600 | |||
Process settings | can set up to 32 steps and 256 cycles | |||
Charging mode | constant current, constant voltage | |||
Charging end conditions | voltage, current, time, capacity Discharge mode constant current | |||
Discharge mode | constant current | |||
Discharge end conditions | voltage, time, capacity | |||
Protection functions | overvoltage, undervoltage, overcurrent, undercurrent, overcapacity, etc. | |||
Time range | arbitrarily set within 0-30000 minutes | |||
Time accuracy | ≤1% | |||
Sampling inspection cycle | ≤5s | ≤3s | ≤8s | ≤3s |
Minimum data recording frequency | ≤5s | ≤8s | ||
Battery sorting | according to capacity, time, discharge platform, etc. | |||
Data processing | Data, graphs and cycle diagrams |