Availability: | |
---|---|
Quantity: | |
TCS33-128/30A
TERTRON
Description
TCS33-128/30A cylindrical battery energy-saving capacity grader is carefully designed for large cylindrical batteries and meets the strict requirements of cylindrical power battery grading. Designed for precision and efficiency, the machine sets the standard for the accuracy of battery grading technology and is mainly used for capacity separation, capacity testing and cycle life testing of cylindrical battery cells.
Key Features
- Tailored for big cylindrical power batteries, ensuring compatibility with various sizes and chemistries.
- Each battery test channel has an independent voltage and current loop design, which is stable and impact-free. It can realize functions such as start, stop, pause, continue and protection for a single battery channel.
- Advanced energy-saving capacity grading technology for accurate assessment of battery performance.
- Customizable grading parameters to accommodate specific battery chemistries and performance specifications.
- Automated sorting processes streamline operations and maximize throughput.
- High precision measurement tools provide reliable grading results in real-time.
- Comprehensive safety features ensure operator safety and prevent accidents.
- Intuitive user interface simplifies operation and monitoring for enhanced efficiency.
- Quality assurance mechanisms categorize batteries based on performance metrics, ensuring adherence to strict quality standards.
Product Parameters
Structure Of Equipment | |||
Device Channel | 128 channels | Overall Dimension | Length 900mm× Width 860mm× Height 1840mm |
Support Battery Specifications | Diameter: 18-32mm; Length: 65-180mm Diameter: 32-60mm; Length: 80-160mm | ||
Working Power Supply | Three-phase 5 wire system AC380V±10%,50HZ | ||
Working Power Consumption | ≤24 KW | ||
Charging Efficiency Of Whole Machine | Charge≥80%; discharge≥70% | ||
Work Environment | Indoors, temperature is 10-30℃ under air convection | ||
Channel Parameters | |||
Voltage Measurement Range | DC 0~5V | Battery Voltage Range | Charge DC 0mV~4.5V;Discharge DC 2~4.5V |
Constant Voltage Range | DC 2~4.5V | Voltage Accuracy | ±(0.5% Reading+0.5% Full Degre) |
Voltage Resolution | 0.1mV | Voltage Stability | ≤(±1mV) |
Current Range | Charge DC 60mA~30A;Discharge DC 60mA~30A | ||
Current Accuracy | ±(0.5% Reading+0.5% Full Degre) | Current Stability | ≤(±1mA) |
Software Function | |||
Control Method | Computer Control Equipment Work, whole cabinet control/single board startup/single point startup, with scanning system | ||
Communication Method | 485 serial port communication (baud rate 57600)/TCP communication/chart | ||
Process Settings | Up to 64 work steps and 256 cycles can be set, with the function of nested loops | ||
Charging Mode | Constant Current, Constant Voltage, Constant Current and Constant Voltage | ||
Charging Cut-off Conditions | Voltage, current, time, capacity, -△V | ||
Discharge Mode | Constant current, constant power, constant resistance | ||
Discharge Cut-off Conditions | voltage, time, capacity | ||
Time Limit | 0~3000 minutes/work step, time unit is min | ||
Time Accuracy | ≤±1%0 | ||
Sampling Inspection Cycle | 1s-60s optional |
Description
TCS33-128/30A cylindrical battery energy-saving capacity grader is carefully designed for large cylindrical batteries and meets the strict requirements of cylindrical power battery grading. Designed for precision and efficiency, the machine sets the standard for the accuracy of battery grading technology and is mainly used for capacity separation, capacity testing and cycle life testing of cylindrical battery cells.
Key Features
- Tailored for big cylindrical power batteries, ensuring compatibility with various sizes and chemistries.
- Each battery test channel has an independent voltage and current loop design, which is stable and impact-free. It can realize functions such as start, stop, pause, continue and protection for a single battery channel.
- Advanced energy-saving capacity grading technology for accurate assessment of battery performance.
- Customizable grading parameters to accommodate specific battery chemistries and performance specifications.
- Automated sorting processes streamline operations and maximize throughput.
- High precision measurement tools provide reliable grading results in real-time.
- Comprehensive safety features ensure operator safety and prevent accidents.
- Intuitive user interface simplifies operation and monitoring for enhanced efficiency.
- Quality assurance mechanisms categorize batteries based on performance metrics, ensuring adherence to strict quality standards.
Product Parameters
Structure Of Equipment | |||
Device Channel | 128 channels | Overall Dimension | Length 900mm× Width 860mm× Height 1840mm |
Support Battery Specifications | Diameter: 18-32mm; Length: 65-180mm Diameter: 32-60mm; Length: 80-160mm | ||
Working Power Supply | Three-phase 5 wire system AC380V±10%,50HZ | ||
Working Power Consumption | ≤24 KW | ||
Charging Efficiency Of Whole Machine | Charge≥80%; discharge≥70% | ||
Work Environment | Indoors, temperature is 10-30℃ under air convection | ||
Channel Parameters | |||
Voltage Measurement Range | DC 0~5V | Battery Voltage Range | Charge DC 0mV~4.5V;Discharge DC 2~4.5V |
Constant Voltage Range | DC 2~4.5V | Voltage Accuracy | ±(0.5% Reading+0.5% Full Degre) |
Voltage Resolution | 0.1mV | Voltage Stability | ≤(±1mV) |
Current Range | Charge DC 60mA~30A;Discharge DC 60mA~30A | ||
Current Accuracy | ±(0.5% Reading+0.5% Full Degre) | Current Stability | ≤(±1mA) |
Software Function | |||
Control Method | Computer Control Equipment Work, whole cabinet control/single board startup/single point startup, with scanning system | ||
Communication Method | 485 serial port communication (baud rate 57600)/TCP communication/chart | ||
Process Settings | Up to 64 work steps and 256 cycles can be set, with the function of nested loops | ||
Charging Mode | Constant Current, Constant Voltage, Constant Current and Constant Voltage | ||
Charging Cut-off Conditions | Voltage, current, time, capacity, -△V | ||
Discharge Mode | Constant current, constant power, constant resistance | ||
Discharge Cut-off Conditions | voltage, time, capacity | ||
Time Limit | 0~3000 minutes/work step, time unit is min | ||
Time Accuracy | ≤±1%0 | ||
Sampling Inspection Cycle | 1s-60s optional |