Availability: | |
---|---|
Quantity: | |
TCS14-512/3A
TERTRON
Description
TCS14-512/3A Pouch Battery Traditional Linear Feedback Capacity Grading Machine is primarily used for capacity separation, capacity testing and cycle life testing of pouch cells. It is meticulously designed to meet the stringent requirements of grading soft-pack cells. Engineered for precision and efficiency, this machine sets the standard for accuracy in battery grading technology.
Key Features
- Tailored for pouch battery cell/battery pack, ensuring compatibility with various sizes and chemistries.
- Each battery test channel has an independent voltage and current loop design, which is stable and impact-free. It can realize functions such as start, stop, pause, continue and protection for a single battery channel.
- Advanced conventional linear/energy-saving capacity grading technology for accurate assessment of battery performance.
- Customizable grading parameters to accommodate specific battery chemistries and performance specifications.
- Automated sorting processes streamline operations and maximize throughput.
- High precision measurement tools provide reliable grading results in real-time.
- Comprehensive safety features ensure operator safety and prevent accidents.
- Intuitive user interface simplifies operation and monitoring for enhanced efficiency.
- Quality assurance mechanisms categorize batteries based on performance metrics, ensuring adherence to strict quality standards.
- The pallet loading and unloading method is fast and reliable; the modular design concept makes it easy to detect and maintain.
Fixture Form Pneumatic clamping /manual quick clamping | ![]() Fixture type 65 Blue & white clasp | ![]() Fixture spacing 85MM | ![]() Support battery Pouch battery | ![]() Dimensions length*width*height 1684*154.4*1840(MM |
please contact us for personalized customization.
Product Parameters
Structure Of Equipment | |||
Device Channel | 512 channels | Overall Dimension | Width 514.4mm× Depth 1684mm× Height 1840mm |
Fixture Form | 65 Blue & white clasp | Fixture Spacing | 85mm |
Support Battery Specifications | Battery tab<65mm, width<85mm | ||
Working Power Supply | Three-phase five-wire system AC380V±10%,50HZ | ||
Working Power Consumption | ≤13 KW | Heat-Dissipating Method | Air cooling |
Work Environment | Indoors, temperature is 10-30℃ under air convection | ||
Channel Parameters | |||
Voltage Measurement Range | DC 0~5V | ||
Battery Voltage Range | Charging DC0~4.5V; discharging DC 4.5~2V | ||
Constant Voltage Range | DC 2~4.5V | ||
Voltage Accuracy | ± (1‰ reading + 1‰ fullness) | ||
Voltage Resolution | 0.1mV | Voltage Stability | ≤(±1mV) |
Current Range | Charge DC30mA~3A;Discharge DC 30mA~3A | ||
Current Accuracy | ± (1‰ reading + 1‰ fullness) | Current Resolution | ≤(±1mA) |
Software Function | |||
Control Method | Computer controlled equipment work, whole cabinet control/single board startup/single point startup, with scanning system | ||
Communication Method | 485 serial port communication (baud rate 57600)/TCP communication | ||
Process Settings | Up to 32 work steps and 256 cycles can be set, with the function of nested loops | ||
Charging Mode | Constant Current, Constant Voltage, Constant Current and Constant Voltage | ||
Charging Cut-off Conditions | Voltage, current, time, capacity, -△V | ||
Discharge Mode | Voltage, current, time, capacity | ||
Discharge Cut-off Conditions | voltage, time, capacity | ||
Time Limit | 0~3000 minutes/work step, time unit is min | ||
Time Accuracy | ≤±1%0 | ||
Sampling Inspection Cycle | 1s-60s optional |
Description
TCS14-512/3A Pouch Battery Traditional Linear Feedback Capacity Grading Machine is primarily used for capacity separation, capacity testing and cycle life testing of pouch cells. It is meticulously designed to meet the stringent requirements of grading soft-pack cells. Engineered for precision and efficiency, this machine sets the standard for accuracy in battery grading technology.
Key Features
- Tailored for pouch battery cell/battery pack, ensuring compatibility with various sizes and chemistries.
- Each battery test channel has an independent voltage and current loop design, which is stable and impact-free. It can realize functions such as start, stop, pause, continue and protection for a single battery channel.
- Advanced conventional linear/energy-saving capacity grading technology for accurate assessment of battery performance.
- Customizable grading parameters to accommodate specific battery chemistries and performance specifications.
- Automated sorting processes streamline operations and maximize throughput.
- High precision measurement tools provide reliable grading results in real-time.
- Comprehensive safety features ensure operator safety and prevent accidents.
- Intuitive user interface simplifies operation and monitoring for enhanced efficiency.
- Quality assurance mechanisms categorize batteries based on performance metrics, ensuring adherence to strict quality standards.
- The pallet loading and unloading method is fast and reliable; the modular design concept makes it easy to detect and maintain.
Fixture Form Pneumatic clamping /manual quick clamping | ![]() Fixture type 65 Blue & white clasp | ![]() Fixture spacing 85MM | ![]() Support battery Pouch battery | ![]() Dimensions length*width*height 1684*154.4*1840(MM |
please contact us for personalized customization.
Product Parameters
Structure Of Equipment | |||
Device Channel | 512 channels | Overall Dimension | Width 514.4mm× Depth 1684mm× Height 1840mm |
Fixture Form | 65 Blue & white clasp | Fixture Spacing | 85mm |
Support Battery Specifications | Battery tab<65mm, width<85mm | ||
Working Power Supply | Three-phase five-wire system AC380V±10%,50HZ | ||
Working Power Consumption | ≤13 KW | Heat-Dissipating Method | Air cooling |
Work Environment | Indoors, temperature is 10-30℃ under air convection | ||
Channel Parameters | |||
Voltage Measurement Range | DC 0~5V | ||
Battery Voltage Range | Charging DC0~4.5V; discharging DC 4.5~2V | ||
Constant Voltage Range | DC 2~4.5V | ||
Voltage Accuracy | ± (1‰ reading + 1‰ fullness) | ||
Voltage Resolution | 0.1mV | Voltage Stability | ≤(±1mV) |
Current Range | Charge DC30mA~3A;Discharge DC 30mA~3A | ||
Current Accuracy | ± (1‰ reading + 1‰ fullness) | Current Resolution | ≤(±1mA) |
Software Function | |||
Control Method | Computer controlled equipment work, whole cabinet control/single board startup/single point startup, with scanning system | ||
Communication Method | 485 serial port communication (baud rate 57600)/TCP communication | ||
Process Settings | Up to 32 work steps and 256 cycles can be set, with the function of nested loops | ||
Charging Mode | Constant Current, Constant Voltage, Constant Current and Constant Voltage | ||
Charging Cut-off Conditions | Voltage, current, time, capacity, -△V | ||
Discharge Mode | Voltage, current, time, capacity | ||
Discharge Cut-off Conditions | voltage, time, capacity | ||
Time Limit | 0~3000 minutes/work step, time unit is min | ||
Time Accuracy | ≤±1%0 | ||
Sampling Inspection Cycle | 1s-60s optional |